Views of Normal Components with Normal Symbols
Approach
Additional symbols for views can be defined for normal components in the database. These are 'real views', so that the pins can also be displayed several times.
Preconditions are:
-
Symbols in the database that can contain several pins at one pin
-
Possibility to define new symbol views in the database for all components and to likewise already define the pin assignment in the database.
Defining Component View in Database
When editing any component in the database, define a view by loading a symbol onto the component sheet using the new Place as View command.
Select the Place as View command on a symbol's context menu in the database tree:
Next, the necessary component pins have to be assigned to the symbol's connections of the view.
This is accomplished by means of the View Assignment... command (on the view's context menu):
|
View Assignment |
|
|---|---|
|
View Symbols |
Displays the complete view structure with its nodes. |
|
Selected devices |
Lists all pins of the active component. Use the check boxes in the right tree to mark the pin/pins that is/are to be assigned to the node selected in the right tree. This makes it also possible to remove already assigned pins (i.e. by un-checking the related appropriate box). If pins are already assigned to another node of the same view, then the check boxes are grayed out and can no longer be assigned. Nodes selected in the left tree, are highlighted graphically on the component sheet (in pink color). |
|
View number |
Defines the default view number. This selection list also displays formboard views. |
|
Use as formboard view |
When the view is to be used as formboard view also, this option must be checked. |
|
Automatic generate |
This options defines whether this view will always be created as 'unplaced' in the project, when taking over the component into the project. The component is also automatically loaded/copied when copying the component. If this is not desired, the view must be deleted afterwards. |
Remarks
-
By double-clicking on an element of the view definition in the database tree, this view is activated and all other elements, which do not belong to this view, will become greyed out.
-
If a symbol is placed on the sheet using the Place as Symbol command (from the component tree) or using Place (from the symbol tree), it is automatically assigned to the current view. In order to create a new view, the Place as View command has to be executed on a symbol once again. Here a new view will be created with the next free view number.
-
In order to later change a view symbol into another view, the View Number option is available (in the Symbol Properties).
-
For the definition of bus pins, which are used more frequently in connection with this functionality, see also Components and Symbols with Bus Pins.
Defining Cross-References between the Component Views (View and Original) in DBE
For the cross-reference of a symbol's pin the following text types can be defined:
-
#1092 (Reference to pin view)
Refers from the pin of the original component to the pin of possible component views
-
#1093 (Reference to pin original)
Refers from the pin of a component view to the pin of the original component
This is done in Database Editor mode. To do so, both text types must be assigned to the symbol's pin upon generating the symbol.
Note
When several component views are to be referred from the same original pin, several texts of the type #1092 (Reference to pin view) must be defined as wildcards. The cross-references are then filled ascendingly in the individual text copies according to the order in which the views are created.
In Database Editor mode, it's possible to assign several texts of the type #1092 Reference to pin view to one pin, however, only one text of the type #1093 Reference to original pin. Regarding bus pins (components) and connector groups (connectors), only the first pin of the list is considered. Pin views of pins are not considered at all.
Example
The text type #1092 on the original component refers to the pins of the component views of the original component:
The text types #1093 of the component views refer to the original component's pin:
Using/Modifying Component in Project
There are two possibilities to load the view into the project:
-
Automatic creation of the view
-
Dynamic creation of the view
In order to automatically create a view in the project, the Automatic generate option in the View Assignment dialog must be activated in Database Editor mode. The defined view is then always created as 'unplaced' when loading the component into the project.
However, a view can also be created dynamically in the project, by activating the command Place New Device Viewin a device's context menu:
|
Place component and create multipolar connection |
Place view and create multipolar connection |
|---|---|
|
|
|
Free choice of the method of work (begin with view):
-
It is also possible to begin with placement and connecting of the view.
-
Cables/wires can be laid in the original view as well.
-
By the use of views, the connections with the signals, conductors, wires are always up-to-date between the views.
-
Laying of the cables on the pins in the single-pole representation
-
Conductors of a cables/wires are laid one after the other.
-
If there are pins in the single-pole representation, which are not connected, then these must be corrected after laying the wires in the single-pole representation (by means of the Connection Properties dialog box).
-
-
Laying the cables in conjunction with terminals
-
Since a terminal has equivalent pins, there are several pins per terminal symbol (depending upon definition). This must be considered when laying the conductors in the single-pole representation of terminals.
-
Conductors/wires on terminals should be laid in the multipolar representation
-