Inserting Disconnecting Points
Handling Signals on Disconnecting Points
A disconnecting point divides a cable harness into two parts. It represents a connector pair which must be assigned to the disconnecting point during the development. The disconnecting point carries the signal flow of the connection. The required connection ports are automatically generated on the disconnecting point. Signals are transmitted one-to-one through the disconnecting point.
To display the connection ports
-
right-click on the disconnecting point, select the Device Properties command from the displayed context menu and switch to the Functional Ports tab.
Same signal are automatically defined as equivalent.
Inserting Disconnecting Points on Existing Connections
The following example describes how to insert a disconnecting point on a topology sheet.
Place wires 1-3 on the connection between installation spaces A1 and A2.
Place a block on this connection. To do so
-
select the Insert -> Block... command in the main menu and
-
select the desired block symbol from the Symbol selection list.
-
Then place the block at the desired position on the connection:
The block divides the connection into two cable harnesses and the signal flow is interrupted by the block.
Right-click on the block and select the Disconnecting Point command from the displayed context menu.
The block becomes a disconnecting point. The interrupted wire connections are automatically duplicated by this inline connector and inserted in the newly created cable harness (wires 4-6). The wire/cable type is retained.
Inserting a disconnecting point has an effect on the Functional Objects tab in the Project Window.
The following image shows the functional objects before inserting the disconnecting point:
... and after inserting the disconnecting point:
-
Cable harnesses H1 and H2 exist after inserting a disconnecting point on cable harness H1
-
The wires from cable harness H1 (1-3) were duplicated and placed on cable harness H2 (4-6)
-
The newly inserted disconnecting point A3 receives the required connection ports automatically
-
The signals of installation spaces A1 and A2 are connected through disconnecting point A3
Splitting Disconnecting Points
Disconnecting points can be split and placed at different positions in the project.
To do so,
-
right-click on the block that will act as the disconnecting point and select the Split Block command in the displayed context menu,
-
place the block at the desired position in the project, for example, on another topology sheet.
-
Then right-click on one of the two split blocks and select the Disconnecting Point command in the displayed context menu.
The split blocks become a disconnecting point.