Introduction to E³.eCheck

E3.check functionality

E3.check is a module for E3.series. It can optionally be used in addition to a E3.schematic or E3.cable license.

 

Regarding electrical checks of connections, routed connections are always superior to logic connections.

 

Checks with E3.check consider SI units only. E3.check requires a separate license. Activation is done automatically, unless E3.view, E3.redliner or E3.logic is started.

 

E3.check makes it possible to calculate the voltage and current at any point in the entire net. The ambient temperature and the specific resistance can also be considered.

 

If the actual data is known, the behavior of electrical components and their interconnections can be alayzed regarding the following topics:

  • open connect lines

  • short circuit to ground

  • inliner not plugged/connected

  • blown fuses

  • short circuit

  • current flow direction

  • fuse melting time and wire ignition time

 

Note

E3.check doesn't support

  • alternating current circuits

  • time-dependent circuits

  • non-linear components

  • display in graphs