Signal References

As E3.series provides the user with the ability to have a schematic drawing comprising multiple sheets, it also provides the ability for connections, and hence signals, to be continued on other sheets.

 

A special type of Signal Reference symbol is used and the symbol displays the location reference (i.e. sheet and co-ordinate) of the continuation of the connection.

 

These symbols are found in the Misc View of the Database Window and are located in the Signal Reference folder.

 

The Signal Reference symbols can be placed in a drawing, just like any other symbol and connections made to them, just like any other connection.

 

There are four types of Signal Reference symbol and for each 'source' symbol there is a corresponding 'destination' symbol. In combination with the same signal, cross-references are created referencing from sheet to sheet.

 

The following signal references are available
SOURCE_* / DESTINATION_* (star)

A source symbol can be associated with any number of destination symbols, and vice versa.

Corresponding signals/references are 'manually' defined using the context menu's Sheet References.

 

SOURCE_UNIQUE / DESTINATION_UNIQUE (unique star)

A source symbol can be associated with any number of destination symbols with the same signal, and vice versa.

Corresponding signals/references are 'manually' defined using the context menu's Sheet References.

 

SOURCE_DIRECT / DESTINATION_DIRECT (point-to-point)

A source symbol can be associated with only one destination. Additional associations, or source/source and destination/destination combinations are impossible.

The destination is 'manually' defined using the context menu's Sheet References.

 

SOURCE_AUTO / DESTINATION_AUTO (automatic)

This is a special form of the point-to-point connection type. It re-orders the cross-references in accordance with the sheet order and signal flow when the sheets are re-ordered or references are moved.

Corresponding signals/references are automatically generated.

 

SOURCE_*_AUTO / DESTINATION_*_AUTO (automatic star)

This is a special form of the star connection type. This source symbol can be associated with several destinations of the same signal, and vice versa.

Corresponding signals/references are automatically generated.

 

A signal cross-reference symbol can be placed and connected in the drawing like any other symbol.

 

Additional Texts on Signal Cross-Reference Symbols

For signal-cross reference symbols it's possible to define an additional text node for

  • Connection Target (#1002)

  • CoreConductor in connection (#1003)

  • Cable type in connection (#1005)

  • Device name (#1010)

  • Number of cables in connection (#1011)

  • Cable in connections (#1012)

  • Number of coreconductors in connection (#1013)

  • Higher level assignment of cable (connection) (#1014)

  • Location of cable (connection) (#1015)

  • Wire group (#1024)

  • Wire (#1025)

  • Cross-section (#1026)

  • Colour (#1027)

  • Item designation (#1062)

  • Assembly device name (#1078)

  • Assembly device designation (#1079)

  • Assembly location (#1080)

  • Assembly higher level assignment (#1081)

  • Assembly item designation (#1082)

  • Assembly component code (#1083)

 

The text is entered automatically.

 

For non-ambiguous targets ('point-to-point' or 'star unique' references), the destination device designated as target, can be entered directly into the text. As soon as a signal reference symbol is connected to that pin of the target device, the cross-reference is generated automatically.

 

Regarding 'Star unique', each target must have the text type #1002 assigned.

 

Example
  • Left-click on the signal cross-reference text and then press the F2 key

     

    or

  • right-click on the signal cross-reference text and select the command Text Properties... from the displayed context menu and select the input field Text in the Text tab.

     

    Or

  • right-click on the signal cross-reference text and select the command Symbol Properties... from the displayed context menu and select the input field Entry in the Connection Target line of the Symbol tab.

     

  • Enter the new connection target and observe the following syntax:

     

    <higher level assignment><location><device designation>:<pin number>

     

    Note:

    If no higher level assignment or location exists, leave them empty.

     

  • The signal cross-reference is now connected with the connection target. When editing the text again, it can be connected to another free connection target.

     

     

    This permits an easy generation of cross-references by specifying the target. This is also possible if the target is not yet available or not yet connected via a signal reference.

     

    Upon connection of the signal reference, the cross-reference is generated.