Component Assignment

This functionality is only available, when a E3.FunctionalDesign or E3.topology license is present!

 

The transition to the wiring plan requires switching from function-oriented to component-oriented structures. Functional blocks (installation spaces in topology) become block components with one or more single or multiple pin connectors. Disconnecting points become connectors.

 

Assigning block components from the database is carried out using the function Functional Assignment.

 

A different fill color can be defined for already assigned functional blocks/installation spaces and disconnecting points in the Settings under Tools -> Settings -> Functional Design/Topology -> Display. The fill color for already assigned functional blocks and diconnecting points can also be defined through the Functional Design/Topology toolbar.

 

The tooltip of assigned functional blocks/installation spaces and disconnecting points displays the complete item designation and the component name.

 

Assigning Devices from Project

A functional block / installation space is assigned the function of a device from the current project.

 

Requirement

The device must not be assigned to another functional block / device.

 

The project must

  • either contain a symbol (with defined Device Designation) of the used functional unit (in this example the symbol of the lamp: ZUK08-10-09) that is placed in the circuit diagram,

  • or contain a device not yet placed, that contains a symbol of the used functional unit (in this example the device of the lamp: 64150SVS).

 

Drag&Drop a functional symbol (symbol with functional unit) onto the functional block / installation space (in this example the symbol of the lamp: ZUK08-10-09)

 

 

  • Right-click on the functional block / installation space and select the Functional Assignment... command from the displayed context menu.

     

    The following dialog appears:

     

  • select the name of the functional unit in the Functional Units section,

  • select the Use devices from project option under List options,

  • and finally select Standard device.

     

    (if predefined in the database, it's also possible to select a block or connector)

     

    The Device designation selection list displays all available devices that contain a symbol of the used functional unit (in this example lamp)

  • Select the device designation from the list and confirm with OK.

     

    The device is now assigned to the functional block / installation space.

     

 

Assigning New Devices from Library

A functional block / installation space is assigned the function of a new device from the database.

 

Requirement

The device with symbol and assigned functional unit must exist in the database (used example from the database: device of switch: 1683.1201)

 

Drag&Drop a functional symbol (symbol with functional unit) onto the functional block / installation space (in this example the symbol of the switch: ZUK07-02-43)

 

 

  • Right-click on the functional block / installation space and select the Functional Assignment... command from the displayed context menu.

     

    The following dialog appears:

     

  • Select the name of the functional unit in the Functional Units section,

  • select the Create new device option under List options,

  • and activate Standard device

     

    ('Block' or Connector' can optionally also be selected).

  • Then select from the Component selection list an existing device with the same function (used example from the database: the device of the switch: 1683.1201)

  • and define a value under Device designation for the new component and confirm with OK.

     

    The new device is now assigned to the functional block / installation space.

     

 

Creating New Dynamic Block

A functional block / installation space is assigned the function of a new dynamic block.

 

Requirement

The functional block / installation space must have an outgoing connection.

  • Right-click on the functional block / installation space and select the Device Properties command from the displayed context menu and switch to the Functional Ports tab in the opened dialog box.

  • Then right-click on the free area and select the Add connection port command from the displayed context menu. Repeat this action until the desired number of connection ports is available.

  • Define the corresponding data and values in the Block connection column, optionally also in Signal and Functional Unit.

     

  • Right-click on the functional block / installation space and select the Functional Assignment... command from the displayed context menu.

     

    The Functional Assignment dialog appears:

  • Select the functional unit's name in the Functional Units section,

  • and activate Create new dynamic block under List options and confirm with OK.

     

     

    The dynamic block created automatically appears in the Device tree view and can be saved to the database, if desired, by right-clicking and selecting the Save to Database... command from the displayed context menu.

 

Creating New Dynamic Connector

A functional block / installation space is assigned the function of a new dynamic connector.

 

Requirement

The functional block / installation space must have an outgoing connection.

  • Right-click on the functional block / installation space and select the Device Properties command from the displayed context menu and switch to the Functional Ports tab in the opened dialog box.

  • Then right-click on the free area and select the Add connection port command from the displayed context menu. Repeat this action until the desired number of connection ports is available.

  • Define the corresponding data and values in the Block connection column, optionally also in Signal and Functional Unit.

     

  • Right-click on the functional block / installation space and select the Functional Assignment... command from the displayed context menu.

     

    The Functional Assignment dialog appears:

  • Select the functional unit's name in the Functional Units section,

  • and activate Create new dynamic connector under List options and confirm with OK.

     

     

    The dynamic connector created automatically appears in the Device tree view and can be saved to the database, if desired, by right-clicking and selecting the Save to Database... command from the displayed context menu.

 

Assigning Connector to Disconnecting Points

For creation of the wiring diagram later on, disconnecting points should be assigned to a connector from the database. Later on, the mating connector of the selected connector component is automatically placed in the Wiring Diagram.

 

Therefore select the desired disconnecting point in the functional design / topology drawing or in the Device tree view and select the command Functional Assignment... from the context menu.

 

The Functional Assignment dialog appears:

  • Select the name of the functional unit in the Functional Units section,

  • select the Use devices from project option under List options,

  • and activate Connector.

  • Define the connector by entering the Device designation and confirm with OK.

     

     

    As soon as the previously assigned connector or its pins are placed, it's no longer possible to change the definitions for the disconnecting point in the Functional Assignment dialog. And the dialog only serves for information.